Skip to Content

Wastewater pump repairs in Albufeira

Repairing two pumps and preventing further faults at a pumping station
November 11, 2026 by
Wastewater pump repairs in Albufeira
Syst-MP, Ana Ribeiro

Syst-MP worked on a wastewater pumping station in Albufeira where both installed pumps were out of service. The diagnosis identified impellers blocked by waste, including rags, accumulated in the wet well.

Repairing the equipment

On the first pump, the work included replacing the bearings and mechanical seal, as well as changing the oil. On the second unit, the work also included rewinding the motor and replacing the capacitor and electrical cable.

The wet well was cleaned with support from a specialist external company, complementing the pump repairs.

Preventing further faults

For this installation, cleaning the wet well once or twice a year was recommended, followed by preventive maintenance of the equipment. The interval should be adjusted to usage conditions and waste accumulation.

Keeping rags and other unsuitable waste out of the wastewater network helps reduce the risk of blocked impellers. Cleaning and maintenance must be carried out by professionals with appropriate equipment.

Syst-MP — always pumping.

About this work

Did Syst-MP also clean the wet well?

Syst-MP repaired the pumps. A specialist external company supported the wet well cleaning.

Technical support in Loulé and the Algarve

Based in Loulé, Syst-MP supports installations, maintenance and equipment supply in the Algarve. Contact our team to discuss the needs of your project.

Contact our team